Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BackgroundGeneral anesthesia may cause atelectasis and deterioration in oxygenation in obese patients. The authors hypothesized that individualized positive end-expiratory pressure (PEEP) improves intraoperative oxygenation and ventilation distribution compared to fixed PEEP.MethodsThis secondary analysis included all obese patients recruited at University Hospital of Leipzig from the multicenter Protective Intraoperative Ventilation with Higher versus Lower Levels of Positive End-Expiratory Pressure in Obese Patients (PROBESE) trial (n = 42) and likewise all obese patients from a local single-center trial (n = 54). Inclusion criteria for both trials were elective laparoscopic abdominal surgery, body mass index greater than or equal to 35 kg/m2, and Assess Respiratory Risk in Surgical Patients in Catalonia (ARISCAT) score greater than or equal to 26. Patients were randomized to PEEP of 4 cm H2O (n = 19) or a recruitment maneuver followed by PEEP of 12 cm H2O (n = 21) in the PROBESE study. In the single-center study, they were randomized to PEEP of 5 cm H2O (n = 25) or a recruitment maneuver followed by individualized PEEP (n = 25) determined by electrical impedance tomography. Primary endpoint was Pao2/inspiratory oxygen fraction before extubation and secondary endpoints included intraoperative tidal volume distribution to dependent lung and driving pressure.ResultsNinety patients were evaluated in three groups after combining the two lower PEEP groups. Median individualized PEEP was 18 (interquartile range, 16 to 22; range, 10 to 26) cm H2O. Pao2/inspiratory oxygen fraction before extubation was 515 (individual PEEP), 370 (fixed PEEP of 12 cm H2O), and 305 (fixed PEEP of 4 to 5 cm H2O) mmHg (difference to individualized PEEP, 145; 95% CI, 91 to 200; P < 0.001 for fixed PEEP of 12 cm H2O and 210; 95% CI, 164 to 257; P < 0.001 for fixed PEEP of 4 to 5 cm H2O). Intraoperative tidal volume in the dependent lung areas was 43.9% (individualized PEEP), 25.9% (fixed PEEP of 12 cm H2O) and 26.8% (fixed PEEP of 4 to 5 cm H2O) (difference to individualized PEEP: 18.0%; 95% CI, 8.0 to 20.7; P < 0.001 for fixed PEEP of 12 cm H2O and 17.1%; 95% CI, 10.0 to 20.6; P < 0.001 for fixed PEEP of 4 to 5 cm H2O). Mean intraoperative driving pressure was 9.8 cm H2O (individualized PEEP), 14.4 cm H2O (fixed PEEP of 12 cm H2O), and 18.8 cm H2O (fixed PEEP of 4 to 5 cm H2O), P < 0.001.ConclusionsThis secondary analysis of obese patients undergoing laparoscopic surgery found better oxygenation, lower driving pressures, and redistribution of ventilation toward dependent lung areas measured by electrical impedance tomography using individualized PEEP. The impact on patient outcome remains unclear.Editor’s perspective

Original publication

DOI

10.1097/aln.0000000000003762

Type

Journal article

Journal

Anesthesiology

Publication Date

06/2021

Volume

134

Pages

887 - 900

Keywords

PROBESE Investigators of the Protective Ventilation Network* and the Clinical Trial Network of the European Society of Anesthesiology, Humans, Obesity, Tidal Volume, Respiration, Artificial, Positive-Pressure Respiration, Pulmonary Atelectasis