Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Overview: SeptiCyte RAPID is an FDA-cleared gene expression test that quantifies host immune response to aid in the diagnosis of sepsis. The test yields a score (the SeptiScore) ranging from 0-15, distributed across four bands (1-4) based on increased likelihood of sepsis. Each band can be characterized by average positive and negative likelihood ratios (LR+ and LR-, respectively) for the discrimination of sepsis versus the non-infectious systemic inflammatory response syndrome (SIRS). Methods: A retrospective analysis of prospectively collected data from a combined cohort of critically ill patients suspected of sepsis (n = 889), recruited across 19 hospitals in the USA and Europe. The analysis quantified the LR+ and LR- parameters as a function of SeptiScore, for discrimination of sepsis vs. SIRS in patients admitted to ICU. Hypotheses: (1) The likelihood ratio (LR) framework provides a clinically useful interpretive approach that complements the previously used SeptiScore banding scheme; (2) Low Band 1 SeptiScores are associated with sufficiently small LR- to support the use of SeptiCyte RAPID as a rule-out test for sepsis; (3) High Band 4 SeptiScores are associated with sufficiently large LR+ to support the use of SeptiCyte RAPID as a rule-in test for sepsis; and (4) SeptiScore-derived LR+ and LR- values can be combined with estimates of pre-test probability (derived from patient characteristics and/or other diagnostic tests) to generate individualized, patient-specific post-test probabilities of sepsis. Results: The SeptiCyte RAPID test demonstrates strong diagnostic performance in distinguishing sepsis from SIRS. The likelihood ratios across different score bands provide clear clinical utility: the median LR+ was 3.26 (range 2.57-4.24) for Band 3, and 6.97 (range 4.35-15.57) for Band 4, providing evidence toward ruling in sepsis at high SeptiScores. Conversely, the median LR- was 0.16 (range 0.14-0.20) for Band 2 and 0.085 (range 0.014-0.16) for Band 1, providing evidence toward ruling out sepsis at low SeptiScores. A higher-resolution analysis of SeptiCyte RAPID performance confirmed these trends by evaluating LR+ and LR- at specific values within each band. The sepsis group was further stratified according to whether patients were classified as blood culture positive (BC+) or blood culture negative (BC-), and the detailed LR+ and LR- analyses were repeated. A monotonic increase in likelihood ratio with increasing SeptiScore was consistently observed, independent of whether sepsis patients were culture-positive, culture-negative, or unstratified with respect to blood culture status. Conclusions: High SeptiScores have correspondingly high LR+ values, and low SeptiScores have correspondingly low LR- values, both of which may have clinical utility. High likelihood ratios for Band 4 SeptiScores, which precede traditional microbiology results, may provide clinicians with early confidence of a sepsis diagnosis and microbiology diagnostic stewardship. Low likelihood ratios for Band 1 SeptiScores may prompt clinicians to consider an alternate diagnosis to sepsis. These are diagnostic-performance-based observations; whether they translate into fewer missed diagnoses or more efficient use of hospital resources has not been directly assessed in this study and will require dedicated clinical outcome studies.

More information Original publication

DOI

10.3390/diagnostics16152450

Type

Journal article

Publication Date

2026-08-01T00:00:00+00:00

Volume

16

Addresses

I, m, m, u, n, e, x, p, r, e, s, s, , I, n, c, ., ,, , S, e, a, t, t, l, e, ,, , W, A, , 9, 8, 1, 0, 9, ,, , U, S, A, .